Off-grid · 1–10 kW
Off-grid solar inverter with built-in charger, 1–10 kW
Transformer-based off-grid machines that start pumps and motors: 1–10 kW, 12/24/48 V, 3× surge.
Off-grid is a different job from grid-tie: there is no utility to absorb surges, so the inverter itself must start a well pump, a fridge compressor or a table saw without collapsing. That is why serious off-grid machines still use a low-frequency transformer and rate their surge at three times continuous output, while grid-tied units race to be lighter and cheaper.
Our range runs 1–10 kW from 12 V to 48 V, with a built-in MPPT solar charger, a 60 A mains/generator charger, and a transfer switch. One box replaces the inverter, charger and changeover panel that a cabin or clinic otherwise assembles from three parts.
Models and ex-works prices
| Model | Rated AC | DC input / surge | Ex-works |
|---|---|---|---|
| PVI-1K-12 | 1 kW | 12 V / 3 kVA | US$ 262 |
| PVI-2K-24 | 2 kW | 24 V / 6 kVA | US$ 338 |
| PVI-3K-24 | 3 kW | 24 V / 9 kVA | US$ 415 |
| PVI-3K-48 | 3 kW | 48 V / 9 kVA | US$ 448 |
| PVI-5K-48 | 5 kW | 48 V / 15 kVA | US$ 618 |
| PVI-8K-48 | 8 kW | 48 V / 24 kVA | US$ 895 |
| PVI-10K-48 | 10 kW | 48 V / 30 kVA | US$ 1145 |
Prices are ex-works, indicative and exclude freight, duty and installation. Model numbers shown are our standard range; OEM labelling is available from 100 units.
What makes this range different
3× surge for 5 seconds
Enough to start a 1.5 kW well pump from a 5 kW machine — the single most common off-grid failure with high-frequency inverters.
Built-in 80 A MPPT charger
PV goes straight into the battery without a separate controller; the display shows array, battery and load on one screen.
Toroidal transformer
Lower idle draw (about 1.2 % of rating) and a quieter supply than laminated-iron budget units — important when the battery is small.
Generator assist and auto-start
When load exceeds the inverter rating the genset supplements it, and a dry contact starts the generator on low battery.
Typical projects
- Cabins, farms and telecom shelters
- Village microgrids and schools
- Well pumps and workshops with high starting surge
Frequently asked questions
How do I size an off-grid inverter?
Add the simultaneous loads, then add the largest motor's starting surge. A cabin with lights, fridge, TV and a 1 hp pump needs about 3 kW continuous and 6 kVA surge — so a 3 kW/9 kVA unit fits.
48 V or 24 V battery bank?
48 V above 3 kW, always: it halves the current and the cable cost. 24 V is fine for 2–3 kW cabins, 12 V only for lighting and small loads.
Can an off-grid inverter charge from the grid?
Yes — the built-in charger takes 230 V mains or generator input at up to 60 A, which is how most hybrid off-grid systems top up in the rainy season.
Not sure which model fits? Send the array size, the site's temperature range and the grid code — we size it and quote in one working day.