Off-grid · 1–10 kW

Off-grid solar inverter with built-in charger, 1–10 kW

Transformer-based off-grid machines that start pumps and motors: 1–10 kW, 12/24/48 V, 3× surge.

Off-grid is a different job from grid-tie: there is no utility to absorb surges, so the inverter itself must start a well pump, a fridge compressor or a table saw without collapsing. That is why serious off-grid machines still use a low-frequency transformer and rate their surge at three times continuous output, while grid-tied units race to be lighter and cheaper.

Our range runs 1–10 kW from 12 V to 48 V, with a built-in MPPT solar charger, a 60 A mains/generator charger, and a transfer switch. One box replaces the inverter, charger and changeover panel that a cabin or clinic otherwise assembles from three parts.

Models and ex-works prices

ModelRated ACDC input / surgeEx-works
PVI-1K-121 kW12 V / 3 kVAUS$ 262
PVI-2K-242 kW24 V / 6 kVAUS$ 338
PVI-3K-243 kW24 V / 9 kVAUS$ 415
PVI-3K-483 kW48 V / 9 kVAUS$ 448
PVI-5K-485 kW48 V / 15 kVAUS$ 618
PVI-8K-488 kW48 V / 24 kVAUS$ 895
PVI-10K-4810 kW48 V / 30 kVAUS$ 1145

Prices are ex-works, indicative and exclude freight, duty and installation. Model numbers shown are our standard range; OEM labelling is available from 100 units.

What makes this range different

3× surge for 5 seconds

Enough to start a 1.5 kW well pump from a 5 kW machine — the single most common off-grid failure with high-frequency inverters.

Built-in 80 A MPPT charger

PV goes straight into the battery without a separate controller; the display shows array, battery and load on one screen.

Toroidal transformer

Lower idle draw (about 1.2 % of rating) and a quieter supply than laminated-iron budget units — important when the battery is small.

Generator assist and auto-start

When load exceeds the inverter rating the genset supplements it, and a dry contact starts the generator on low battery.

Typical projects

  • Cabins, farms and telecom shelters
  • Village microgrids and schools
  • Well pumps and workshops with high starting surge

Frequently asked questions

How do I size an off-grid inverter?

Add the simultaneous loads, then add the largest motor's starting surge. A cabin with lights, fridge, TV and a 1 hp pump needs about 3 kW continuous and 6 kVA surge — so a 3 kW/9 kVA unit fits.

48 V or 24 V battery bank?

48 V above 3 kW, always: it halves the current and the cable cost. 24 V is fine for 2–3 kW cabins, 12 V only for lighting and small loads.

Can an off-grid inverter charge from the grid?

Yes — the built-in charger takes 230 V mains or generator input at up to 60 A, which is how most hybrid off-grid systems top up in the rainy season.

Not sure which model fits? Send the array size, the site's temperature range and the grid code — we size it and quote in one working day.

Ready to specify?

Send the load profile and the site — we return a sized quotation with drawings in one working day.