Sizing, price, phase, battery voltage, certificates and OEM terms — the questions that come up in almost every enquiry, answered without a sales pitch.

General

What is a solar PV inverter and what does it do?

A solar PV inverter converts the direct current (DC) produced by photovoltaic modules into alternating current (AC) that appliances, the grid or a battery system can use. It also tracks the array's maximum power point, provides safety isolation, and monitors yield. Without it, a PV array produces nothing usable.

How much does a solar PV inverter cost in 2026?

Ex-works, our range starts at US$ 96 for a 1 kW single-phase grid-tied unit, about US$ 238 for 5 kW, US$ 498 for 10 kW three-phase, US$ 1,490 for a 12 kW split-phase hybrid, and US$ 4,980 for a 136 kW commercial string inverter. Installed prices are typically 1.6–2.2× the hardware cost once mounting, DC/AC protection, cabling and commissioning are included.

What size inverter do I need?

Size to the array's DC capacity divided by the local irradiance factor, roughly 1.1–1.3× for grid-tied, and to the peak simultaneous load for hybrid and off-grid. A 6 kWp residential array works well on a 5 kW inverter; an off-grid cabin with a 3 kW peak load needs a 3 kW unit with 9 kVA surge.

Which is better, a string inverter or microinverters?

String inverters are cheaper per watt and easier to service; microinverters win on shaded, multi-orientation or frequently expanded roofs. For a clean south-facing array, a string inverter is the better investment; for a complicated roof, module-level conversion pays for itself in yield.

What certifications should a PV inverter have?

IEC 62109-1/-2 for safety, IEC 61727/62116 for grid connection, EN 50549 or VDE-AR-N 4105 for Europe, UL 1741 SB and IEEE 1547 for North America, and CE/UKCA marking. Country-specific grid codes (AS/NZS 4777.2, NRS 097, ABNT NBR 16149) decide whether a unit can legally connect.

Do you offer OEM and ODM?

Yes. We build under customer brands from 100 units: custom label, enclosure colour, firmware splash screen, manual and packaging, plus certificate transfer where the standard allows. Lead time is 20–30 days for repeat models.

On-grid 1-phase

How much does a 5 kW solar PV inverter cost?

Ex-works, a 5 kW single-phase unit runs about US$ 238 in our range. Installed with DC/AC protection, mounting and commissioning, budget US$ 550–900 depending on the country and whether a CT clamp or export limiter is required.

Can I oversize the PV array on a 5 kW inverter?

Yes — up to 150 % DC/AC ratio is allowed on our single-phase range (7.5 kWp of modules on a 5 kW inverter). You lose a little at midday in perfect weather but gain substantially on cloudy mornings and in winter.

Single-phase or three-phase inverter?

If the house has a single-phase supply (most of Europe, Asia, Africa) use single-phase. Above roughly 6 kW, or where the utility requires balanced feed-in, move to a three-phase unit — the extra cost is small and the grid sees balanced current.

On-grid 3-phase

What is the price of a 10 kW three-phase inverter?

About US$ 498 ex-works for our PVS-10K-T. Three-phase machines cost roughly 15–20 % more than an equivalent single-phase unit because of the extra AC stage.

Can a three-phase inverter run on a single-phase supply?

No. The machine expects 400 V three-phase and will fault on missing phases. If the site has only single-phase power, use single-phase inverters, or a hybrid unit with a managed phase-balance output.

Do I need a type A or type B RCD?

Type A is sufficient for transformerless inverters unless the local code or utility specifies type B; our units include integrated DC residual-current monitoring to IEC 62109-2.

Hybrid LV 48V

What size hybrid inverter do I need for a house?

Size to the peak simultaneous load, not the monthly kWh: a typical European home needs 5 kW, a US home with central air 8–10 kW, an off-grid cabin 3 kW. Battery size then follows the night-time consumption.

Can a 48 V hybrid inverter run without a battery?

Most of our hybrid range can run PV-only in grid-tied mode with the battery input disabled, which lets you add storage later. Off-grid operation always needs a battery.

Does a hybrid inverter work with my existing solar?

Yes, if the existing array's voltage sits inside the MPPT window (120–500 V on the 48 V models). Existing grid-tied inverters cannot be retrofitted into the hybrid — the hybrid replaces them, and the old unit can be kept as a spare or sold.

Hybrid HV

HV or LV battery — which should I choose?

Below about 10 kWh and 6 kW, 48 V is cheaper and easier to service. Above that, HV wins on cable size, efficiency and parallel scalability. Commercial projects above 20 kWh are almost always HV.

Can I mix battery brands on a high-voltage hybrid?

No. The inverter must speak the battery's BMS protocol, and HV packs are series-stacked, so one brand and one model per stack. Choose the battery first, then confirm the inverter's protocol list.

Is a high-voltage hybrid inverter safe to install?

Yes, with the same DC precautions as a string inverter: 800 V DC is lethal if mishandled, so the battery must have an integral breaker and the installer must be qualified for DC work above 120 V.

Split-phase 120/240

Can I use a European inverter in the US?

Not legally for grid-tie: it lacks UL 1741 listing and produces 230 V single-phase, not 120/240 V split-phase. Off-grid only, and even then the charger and breakers must be NRTL-listed.

What size split-phase inverter for a US home?

8 kW covers most homes without electric resistance heat; 10–12 kW if there is a heat pump, EV charger and well pump. Above 12 kW, parallel two units rather than buying a commercial machine.

Does it work with a 120 V-only generator?

The generator input accepts 120/240 V split-phase. A 120 V-only generator can charge the battery through a separate charger but cannot pass through to 240 V loads.

Off-grid

How do I size an off-grid inverter?

Add the simultaneous loads, then add the largest motor's starting surge. A cabin with lights, fridge, TV and a 1 hp pump needs about 3 kW continuous and 6 kVA surge — so a 3 kW/9 kVA unit fits.

48 V or 24 V battery bank?

48 V above 3 kW, always: it halves the current and the cable cost. 24 V is fine for 2–3 kW cabins, 12 V only for lighting and small loads.

Can an off-grid inverter charge from the grid?

Yes — the built-in charger takes 230 V mains or generator input at up to 60 A, which is how most hybrid off-grid systems top up in the rainy season.