solarpvinverter.comPV inverters, 1-500 kW

Module-level · 600–2400 W

Solar microinverter, 600–2400 W

Module-level conversion for shaded or complicated roofs: 1–4 MPPTs per unit, 97 % efficiency, IP67.

A microinverter bolts to the module rail and converts DC to AC right there, so every panel works at its own maximum power point. On a roof with chimney shading, three orientations, or a module added two years later, that is worth 10–25 % of annual yield compared with one string inverter.

The trade-off is cost per watt and the number of electronic boxes on the roof. Our 600–2400 W range covers single-module residential units up to four-module commercial units, all IP67 with a 25-year design life and a monitoring gateway that maps the array per module.

Models and ex-works prices

ModelAC outputInputs / MPPTEx-works
PVM-600600 W1 / 1US$ 62
PVM-12001200 W2 / 2US$ 105
PVM-16001600 W2 / 2US$ 128
PVM-20002000 W4 / 2US$ 152
PVM-24002400 W4 / 4US$ 186

Prices are ex-works, indicative and exclude freight, duty and installation. Model numbers shown are our standard range; OEM labelling is available from 100 units.

What makes this range different

Per-module MPPT

One shaded panel does not drag the string down; monitoring shows exactly which module underperforms.

No high-voltage DC on the roof

Only 230 V AC leaves the array, which removes the arc-fault and rapid-shutdown problem entirely.

IP67, -40 to +65 °C

Potting and a cast housing rated for rooftop heat soak, not just a splash-proof enclosure.

PLC or Wi-Fi gateway

One gateway per 30 units; per-module data, firmware updates and export limiting.

Typical projects

  • Shaded or multi-orientation roofs
  • Systems expanded module by module
  • Installations where DC on the roof is not allowed

Frequently asked questions

Are microinverters worth the extra cost?

On a complicated or shaded roof, usually yes: 10–25 % more yield plus module-level monitoring. On a clean south-facing array with no shading, a string inverter is cheaper per kWh and easier to service.

How many modules can one microinverter take?

Our PVM-2000 and PVM-2400 take four modules with two to four MPPTs; the 600 W unit takes one. Match the module's Isc to the unit's input rating — 2 × 550 W modules need the 1200 W model at minimum.

What happens when a microinverter fails?

It is replaced individually, in minutes, without touching the rest of the array — the main advantage over a string inverter, which takes the whole array down.

Not sure which model fits? Send the array size, the site's temperature range and the grid code — we size it and quote in one working day.

Ready to specify?

Send the load profile and the site — we return a sized quotation with drawings in one working day.