Module-level · 600–2400 W
Solar microinverter, 600–2400 W
Module-level conversion for shaded or complicated roofs: 1–4 MPPTs per unit, 97 % efficiency, IP67.
A microinverter bolts to the module rail and converts DC to AC right there, so every panel works at its own maximum power point. On a roof with chimney shading, three orientations, or a module added two years later, that is worth 10–25 % of annual yield compared with one string inverter.
The trade-off is cost per watt and the number of electronic boxes on the roof. Our 600–2400 W range covers single-module residential units up to four-module commercial units, all IP67 with a 25-year design life and a monitoring gateway that maps the array per module.
Models and ex-works prices
| Model | AC output | Inputs / MPPT | Ex-works |
|---|---|---|---|
| PVM-600 | 600 W | 1 / 1 | US$ 62 |
| PVM-1200 | 1200 W | 2 / 2 | US$ 105 |
| PVM-1600 | 1600 W | 2 / 2 | US$ 128 |
| PVM-2000 | 2000 W | 4 / 2 | US$ 152 |
| PVM-2400 | 2400 W | 4 / 4 | US$ 186 |
Prices are ex-works, indicative and exclude freight, duty and installation. Model numbers shown are our standard range; OEM labelling is available from 100 units.
What makes this range different
Per-module MPPT
One shaded panel does not drag the string down; monitoring shows exactly which module underperforms.
No high-voltage DC on the roof
Only 230 V AC leaves the array, which removes the arc-fault and rapid-shutdown problem entirely.
IP67, -40 to +65 °C
Potting and a cast housing rated for rooftop heat soak, not just a splash-proof enclosure.
PLC or Wi-Fi gateway
One gateway per 30 units; per-module data, firmware updates and export limiting.
Typical projects
- Shaded or multi-orientation roofs
- Systems expanded module by module
- Installations where DC on the roof is not allowed
Frequently asked questions
Are microinverters worth the extra cost?
On a complicated or shaded roof, usually yes: 10–25 % more yield plus module-level monitoring. On a clean south-facing array with no shading, a string inverter is cheaper per kWh and easier to service.
How many modules can one microinverter take?
Our PVM-2000 and PVM-2400 take four modules with two to four MPPTs; the 600 W unit takes one. Match the module's Isc to the unit's input rating — 2 × 550 W modules need the 1200 W model at minimum.
What happens when a microinverter fails?
It is replaced individually, in minutes, without touching the rest of the array — the main advantage over a string inverter, which takes the whole array down.
Not sure which model fits? Send the array size, the site's temperature range and the grid code — we size it and quote in one working day.