Guide
Certificates, testing and what the warranty really covers
A certificate proves a design passed a test once. A test line proves every unit does. Both matter, and both are documented per serial number.
Certificates are the entry ticket; the test sequence behind them is what determines field failure rate. Every unit we ship goes through the same eight-station line, and the report travels with the serial number.
Certificates we hold
| Standard | Scope | Status |
|---|---|---|
| IEC 62109-1 / -2 | Safety of PV power converters | Certified, TÜV |
| IEC 61727 / 62116 | Utility interface, anti-islanding | Tested |
| EN 50549-1/-2 | European grid connection | Certified |
| VDE-AR-N 4105 | German LV grid code | Certified |
| UL 1741 SB / IEEE 1547 | North American interconnection | Certified (split-phase range) |
| AS/NZS 4777.2 | Australia / New Zealand | Certified |
| NRS 097-2-1 | South Africa | Tested |
| IEC 63027 | DC arc-fault detection | Certified (commercial range) |
The eight-station test line
- Incoming inspection — IGBT/MOSFET lot traceability, capacitor date codes, PCB AOI.
- In-circuit test — every board powered and measured before assembly.
- Functional test — MPPT sweep, AC output THD, relay timing, communication loop.
- Hi-pot — 2.5 kV DC insulation test for 60 s on the DC-AC barrier.
- Burn-in — 4 h at 60 % load and 45 °C ambient, which catches early capacitor and fan failures.
- Grid simulation — anti-islanding, voltage/frequency ride-through, export limiting.
- Final QA — enclosure torque check, IP gasket inspection, label and firmware version audit.
- Packing drop test — 1.2 m drop on a corner, then a repeat functional check on the sampled unit.
Warranty, in plain terms
| Product group | Standard | Extension |
|---|---|---|
| Single-phase grid-tied | 5 years | 10 years on registration |
| Three-phase grid-tied | 5 years | 10 years |
| Hybrid and off-grid | 5 years | 8 years |
| Commercial string | 5 years | 10 years |
| Microinverter | 10 years | 25 years on registration |
| Battery PCS | 3 years | 5 years |
What is not covered, honestly
Lightning damage without external SPD, water ingress from an unsealed gland, units installed in a confined space above 50 °C, and firmware modified by the customer. Those four account for most of the warranty claims we reject, and each is avoidable at installation.