solarpvinverter.comPV inverters, 1-500 kW

Storage · 3–12 kW

48 V hybrid solar inverter, 3–12 kW

The off-grid-capable hybrid: 48 V battery bank, dual MPPT, 10 ms backup, works with or without the grid.

A 48 V hybrid inverter is the most practical storage architecture for a house: the battery voltage is low enough to be safe to install and high enough to keep currents manageable, and the machine can operate grid-tied, off-grid, or both at once. Ours runs 3–12 kW with two to four MPPTs and a 10 ms transfer to backup.

The design decision that matters is how the inverter treats the grid. A good hybrid can be set to zero-export, to export surplus, to charge only from PV, or to time-shift cheap night tariff into the evening peak. All of that is configuration, not extra hardware — which is why we expose it in the local app rather than locking it behind a cloud account.

Models and ex-works prices

ModelRated ACBattery / MPPTEx-works
PVH-3K-483 kW48 V / 2US$ 445
PVH-4K-484 kW48 V / 2US$ 512
PVH-5K-485 kW48 V / 2US$ 578
PVH-6K-486 kW48 V / 2US$ 648
PVH-8K-488 kW48 V / 3US$ 795
PVH-10K-4810 kW48 V / 3US$ 928
PVH-12K-4812 kW48 V / 4US$ 1085

Prices are ex-works, indicative and exclude freight, duty and installation. Model numbers shown are our standard range; OEM labelling is available from 100 units.

What makes this range different

10 ms backup transfer

Faster than a UPS handover for most loads; computers and routers ride through an outage without rebooting.

Up to 6 units in parallel

6 × 12 kW gives 72 kW three-phase-capable capacity for a small hotel or clinic, with one battery bank shared.

Generator input with auto-start

Dry contact starts a genset when the battery hits a set depth of discharge — the standard architecture for weak-grid sites.

Works with lead-acid or lithium

User-selectable charge profiles plus CAN/RS485 for the common 48 V lithium BMS protocols; no brand lock-in.

Typical projects

  • Homes with 5-20 kWh of 48 V storage
  • Off-grid cabins and clinics with generator backup
  • Weak-grid sites with daily outages

Frequently asked questions

What size hybrid inverter do I need for a house?

Size to the peak simultaneous load, not the monthly kWh: a typical European home needs 5 kW, a US home with central air 8–10 kW, an off-grid cabin 3 kW. Battery size then follows the night-time consumption.

Can a 48 V hybrid inverter run without a battery?

Most of our hybrid range can run PV-only in grid-tied mode with the battery input disabled, which lets you add storage later. Off-grid operation always needs a battery.

Does a hybrid inverter work with my existing solar?

Yes, if the existing array's voltage sits inside the MPPT window (120–500 V on the 48 V models). Existing grid-tied inverters cannot be retrofitted into the hybrid — the hybrid replaces them, and the old unit can be kept as a spare or sold.

Not sure which model fits? Send the array size, the site's temperature range and the grid code — we size it and quote in one working day.

Ready to specify?

Send the load profile and the site — we return a sized quotation with drawings in one working day.