Storage · 3–12 kW
48 V hybrid solar inverter, 3–12 kW
The off-grid-capable hybrid: 48 V battery bank, dual MPPT, 10 ms backup, works with or without the grid.
A 48 V hybrid inverter is the most practical storage architecture for a house: the battery voltage is low enough to be safe to install and high enough to keep currents manageable, and the machine can operate grid-tied, off-grid, or both at once. Ours runs 3–12 kW with two to four MPPTs and a 10 ms transfer to backup.
The design decision that matters is how the inverter treats the grid. A good hybrid can be set to zero-export, to export surplus, to charge only from PV, or to time-shift cheap night tariff into the evening peak. All of that is configuration, not extra hardware — which is why we expose it in the local app rather than locking it behind a cloud account.
Models and ex-works prices
| Model | Rated AC | Battery / MPPT | Ex-works |
|---|---|---|---|
| PVH-3K-48 | 3 kW | 48 V / 2 | US$ 445 |
| PVH-4K-48 | 4 kW | 48 V / 2 | US$ 512 |
| PVH-5K-48 | 5 kW | 48 V / 2 | US$ 578 |
| PVH-6K-48 | 6 kW | 48 V / 2 | US$ 648 |
| PVH-8K-48 | 8 kW | 48 V / 3 | US$ 795 |
| PVH-10K-48 | 10 kW | 48 V / 3 | US$ 928 |
| PVH-12K-48 | 12 kW | 48 V / 4 | US$ 1085 |
Prices are ex-works, indicative and exclude freight, duty and installation. Model numbers shown are our standard range; OEM labelling is available from 100 units.
What makes this range different
10 ms backup transfer
Faster than a UPS handover for most loads; computers and routers ride through an outage without rebooting.
Up to 6 units in parallel
6 × 12 kW gives 72 kW three-phase-capable capacity for a small hotel or clinic, with one battery bank shared.
Generator input with auto-start
Dry contact starts a genset when the battery hits a set depth of discharge — the standard architecture for weak-grid sites.
Works with lead-acid or lithium
User-selectable charge profiles plus CAN/RS485 for the common 48 V lithium BMS protocols; no brand lock-in.
Typical projects
- Homes with 5-20 kWh of 48 V storage
- Off-grid cabins and clinics with generator backup
- Weak-grid sites with daily outages
Frequently asked questions
What size hybrid inverter do I need for a house?
Size to the peak simultaneous load, not the monthly kWh: a typical European home needs 5 kW, a US home with central air 8–10 kW, an off-grid cabin 3 kW. Battery size then follows the night-time consumption.
Can a 48 V hybrid inverter run without a battery?
Most of our hybrid range can run PV-only in grid-tied mode with the battery input disabled, which lets you add storage later. Off-grid operation always needs a battery.
Does a hybrid inverter work with my existing solar?
Yes, if the existing array's voltage sits inside the MPPT window (120–500 V on the 48 V models). Existing grid-tied inverters cannot be retrofitted into the hybrid — the hybrid replaces them, and the old unit can be kept as a spare or sold.
Not sure which model fits? Send the array size, the site's temperature range and the grid code — we size it and quote in one working day.