Types of solar PV inverters — and how to choose in three questions
Ten architectures, one decision tree. Is there a grid? Is there a battery? What does the roof look like? Answer those and the type is decided; the rest is sizing.
There are ten inverter architectures sold today, and nine of them are the wrong answer for any given project. The table sorts them by what they actually do, and the three questions below decide the choice in under a minute.
The ten types, compared
| Type | Range | What it does | Watch out for |
|---|---|---|---|
| Grid-tied single-phase | 1-6 kW | No battery; export to grid | Cheapest per kW; no backup |
| Grid-tied three-phase | 5-25 kW | Balanced 400 V feed-in | Needs three-phase supply |
| Hybrid, 48 V battery | 3-12 kW | Storage with 10 ms backup | Battery current limits scale |
| Hybrid, high voltage | 5-30 kW | Commercial storage, 160-800 V | Battery and inverter must match |
| Split-phase 120/240 V | 8-12 kW | North American panels | US/Canada only, UL required |
| Off-grid | 1-10 kW | No grid at all, 3x surge | Lower efficiency, heavier |
| Microinverter | 0.6-2.4 kW | Per-module MPPT, no DC on roof | Highest cost per watt |
| Commercial string | 30-136 kW | Factory and warehouse roofs | Needs string design skill |
| Battery PCS | 30-500 kW | Bidirectional, grid-forming | No PV input of its own |
| Pump VFD | 0.75-75 kW | Irrigation, dry-run protection | Single-purpose machine |
Question 1: is there a grid?
If there is no grid, or it is unreliable for more than a few hours a week, you need an off-grid or hybrid machine. A grid-tied inverter without a battery shuts down the moment the grid does — by law, not by fault. That surprises buyers every week: a 10 kW grid-tied system provides exactly zero backup during an outage.
Question 2: is there a battery?
No battery: grid-tied, and choose single or three phase by the supply. Battery now or later: a hybrid inverter, sized to the battery voltage. 48 V below 10 kWh, high voltage above. A hybrid can run PV-only first and accept storage later, which is why it outsells pure grid-tied in markets with unreliable supply.
Question 3: what does the roof look like?
A clean south-facing plane with no shade: one string inverter, two MPPTs at most. Three orientations, a chimney, or a tree that will grow: microinverters, or DC optimisers on a string inverter. On commercial roofs above 30 kW the string inverter wins on cost and serviceability, provided the strings are designed per orientation.
What buyers get wrong
- Sizing by kWp instead of by load. A 10 kWp array on a 5 kW inverter is fine grid-tied; it is a mistake off-grid, where the battery and the inverter must carry the evening load.
- Ignoring the temperature derating. A 45 °C plant room costs 8-12 % of output on a machine rated at 25 °C. Read the derating curve, not the headline.
- Buying a cheap unit for a 20-year project. The inverter is 8-12 % of system cost and 60 % of the failures. It is the wrong component to value-engineer.
Frequently asked questions
Which solar inverter is best for a home?
A 5-10 kW hybrid if you want backup or plan storage; a single-phase grid-tied unit if the grid is stable and cheap. Both are covered in our single-phase range.
Is a hybrid inverter worth it?
Where outages are frequent or export rates are poor, yes — it lets you store and self-consume. Where the grid is reliable and net metering pays well, a grid-tied unit returns more per dollar.
What is the difference between on-grid and off-grid inverter?
On-grid synchronises to the utility and shuts down without it. Off-grid forms its own voltage and current, needs a battery, and is built to start motors — at the cost of efficiency and weight.