Water · 0.75–75 kW
Solar pump inverter, 0.75–75 kW
Irrigation without diesel: MPPT-driven VFD for 3-phase pumps, dry-run protection, 0.75–75 kW.
A solar pump inverter is a variable-frequency drive fed by PV instead of the grid: it tracks the array's maximum power point and varies the pump speed instead of switching on and off. That alone extends motor life and lets a smaller array lift the same water, because the pump runs longer at lower head.
Our range covers 0.75–75 kW with DC and AC dual input, so the pump runs from solar by day and from mains or a generator at night, switching automatically. Dry-run protection, over-voltage and lightning protection are built in — the three failures that kill pumps in the field.
Models and ex-works prices
| Model | Pump motor | DC input / output | Ex-works |
|---|---|---|---|
| PVP-0.75 | 0.75 kW | 150–400 V / 3×220 V | US$ 108 |
| PVP-1.5 | 1.5 kW | 200–400 V / 3×220 V | US$ 128 |
| PVP-2.2 | 2.2 kW | 250–450 V / 3×380 V | US$ 158 |
| PVP-4 | 4 kW | 300–500 V / 3×380 V | US$ 218 |
| PVP-7.5 | 7.5 kW | 350–750 V / 3×380 V | US$ 348 |
| PVP-15 | 15 kW | 350–750 V / 3×380 V | US$ 598 |
| PVP-37 | 37 kW | 450–800 V / 3×380 V | US$ 1180 |
| PVP-75 | 75 kW | 450–800 V / 3×380 V | US$ 2080 |
Prices are ex-works, indicative and exclude freight, duty and installation. Model numbers shown are our standard range; OEM labelling is available from 100 units.
What makes this range different
99 % MPPT efficiency
Wide 150–800 V DC window accepts series strings sized to the pump, not to a battery.
Dry-run and low-water protection
Detects low current and stops the pump before the motor overheats; restarts automatically when the water returns.
AC/DC dual input
Solar by day, grid or genset by night, with automatic source switching and no manual changeover.
Soft start, no surge
VFD ramps the motor, so a 7.5 kW pump needs no 22 kW generator and no starting capacitor.
Typical projects
- Irrigation from boreholes and canals
- Drinking-water supply for villages
- Fish farms and pool circulation
Frequently asked questions
How much does a solar pump system cost?
A 7.5 kW pump inverter is about US$ 348 ex-works; with 10 kWp of modules, mounting and the pump itself, a turnkey 7.5 kW system lands around US$ 6,000–9,000 depending on borehole depth.
Can I use a normal VFD with solar panels?
No. A standard VFD expects a stiff AC supply and will trip on the array's current-limited output. A solar pump inverter controls the DC input directly and tracks the MPP.
What array size for a 7.5 kW pump?
Roughly 10–12 kWp, sized so the DC voltage stays inside the 350–750 V window at the site's highest temperature. Oversizing the array by 30 % extends pumping hours into cloudy weather.
Not sure which model fits? Send the array size, the site's temperature range and the grid code — we size it and quote in one working day.