Storage · 30–500 kW
Battery PCS, 30–500 kW
Grid-scale and C&I storage converter: 30–500 kW bidirectional, 1000 V DC, four-quadrant, grid-forming option.
A PCS is an inverter that works in both directions: it charges a battery from the grid or PV, and discharges it back. Commercial storage, peak shaving, demand-charge management and microgrids are all built on this box, and its specification is written in cycles and response time rather than efficiency alone.
Our range covers 30–500 kW at 400 V AC with a 600–1000 V DC battery window, four-quadrant operation (real and reactive power in both directions), and an optional grid-forming mode for microgrids and weak-grid sites.
Models and ex-works prices
| Model | Rated power | DC window / AC | Ex-works |
|---|---|---|---|
| PCS-30 | 30 kW | 600–1000 V / 400 V | US$ 5480 |
| PCS-50 | 50 kW | 600–1000 V / 400 V | US$ 7980 |
| PCS-100 | 100 kW | 600–1000 V / 400 V | US$ 12800 |
| PCS-125 | 125 kW | 600–1000 V / 400 V | US$ 15200 |
| PCS-250 | 250 kW | 600–1000 V / 400 V | US$ 24600 |
| PCS-500 | 500 kW | 600–1000 V / 400 V | US$ 43800 |
Prices are ex-works, indicative and exclude freight, duty and installation. Model numbers shown are our standard range; OEM labelling is available from 100 units.
What makes this range different
Four-quadrant, ±1 power factor
Provides reactive power and voltage support, not just watts — increasingly a requirement for grid connection.
< 20 ms response
Fast enough for frequency response and demand-charge management, not just arbitrage.
Grid-forming mode
Sets voltage and frequency for an islanded microgrid, with droop control and black-start capability.
Liquid-cooled option above 250 kW
Keeps the power stack at a stable temperature in 50 °C plant rooms and doubles the service interval.
Typical projects
- Commercial battery storage 100 kWh-2 MWh
- Microgrids and weak-grid stabilisation
- Demand-charge reduction in factories
Frequently asked questions
What is the difference between a PCS and a hybrid inverter?
A hybrid inverter is a residential device with PV MPPTs and a low-voltage battery port. A PCS has no PV input: it couples a high-voltage battery to the grid at commercial scale, with reactive power and grid-support functions.
Can a PCS work as a UPS?
With the grid-forming option, yes — but check the transfer time against your load. For data centres you need a dedicated UPS; for a factory, a 20 ms PCS transition is usually acceptable.
How do I size a PCS for peak shaving?
Size to the power you need to shave off the demand peak, not to the battery energy. A 100 kW PCS with a 200 kWh battery shaves 100 kW for two hours — usually the sweet spot for demand charges.
Not sure which model fits? Send the array size, the site's temperature range and the grid code — we size it and quote in one working day.